Project Description
400kw-600kw soft starter

Introduction
The motor soft starter is the use of power electronic technology, micro processing technology and modern control theory and the design of new production equipment starting with the current international advanced level. The product can effectively limit the starting of AC asynchronous motor starting current, which can be widely used in fan and water pump, conveying type and the compressor load, is the traditional star delta conversion, autotransformer step-down buck, magnetron device ideal products.
A motor soft starter is a device used with AC electrical motors to temporarily reduce the load and torque in the power train and electric current surge of the motor during start-up.
Machine tool manufacturing:
CNC lathe spindle drive, automatic lathe spindle drive, universal lathe spindle drive, vertical lathe spindle drive, rotary grinding machine spindle drive, integer machine drive etc..
Building materials industry:
Air blower, mixed soil pump, belt conveyor, air compressor, cement crusher. Raw mill, cement mill, vibrating feeder, hoisting machinery. Conveyor belt. The ball mill, the fire hydrant pump etc..
Mining:
Crushing machine, air compressor. High pressure water injection pump, conveyor belt, compressor, crane, mud pump etc ..
Chemical engineering:
Heat pump.Centrifuge Mixer, compressor, blower, refrigerating machine. Air compressor, reclaimer etc.,
Metallurgy:
The conveyor belt, hoisting machine, feeder, blast machine, rolling machine etc..
Paper printing:
Grinding machine, machine, blower, pump etc..
Medicine:
Refrigerating machine, compressor, centrifuge etc..
Sewage treatment:
Centrifugal pump, aeration machine. Blower. Water pump etc..
Power energy:
Boiler drum blower, conveyor belt etc..
Logistics:
Solid garage, automatic warehouse, conveyor belt, etc..
Transportation:
Electric vehicles, electric locomotive, ship propulsion, loading and unloading machinery, air compressor, cable car, etc.
Controller model | FU9000S-0R7-2 | FU9000S-1R5-2 | FU9000S-2R2-2 | FU9000S-2R2-4 | FU9000S-004-4 |
Input Data | |||||
PV Source | |||||
Max input Voltage(Voc)[V] | 450 | 800 | |||
Min Input Voltage at mpp[V] | 180 | 350 | |||
Recommended voltage ,at mpp | 280VDC~360VDC | 500VDC~600VDC | |||
Recommended Amps input,at mpp[A] | 4.7 | 7.3 | 10.4 | 6.2 | 11.3 |
Recommended Max Power at mpp[kw] | 1.5 | 3 | 4.4 | 4.4 | 8 |
Alternate AC Generator | |||||
Input voltage | 220/230/240V AC (±15%),single | 380V AC(±15%),three phase | |||
Max Amps(RMS)[A] | 8.2 | 14 | 23 | 5.8 | 10 |
Power and VA capability [kVA] | 2 | 3.1 | 5.1 | 5 | 6.6 |
Output Data | |||||
Rated Output Power[kw] | 0.75 | 1.5 | 2.2 | 2.2 | 4 |
Rated Output Voltage | 220/230/240V,Three phase | ||||
Max Amps(RMS)[A] | 4.5 | 7 | 10 | 5 | 9 |
Output Frequency | 0-50Hz/60Hz | ||||
Protection | |||||
Surge protection,Overvoltage protection,Undervoltage protection,Locked pump protection, Open circuit protection,short circuit protection,Overheated protection,Dry run protection |
|||||
General Data | |||||
Ambient Temperature Range | ﹣20℃~60℃,>45℃,Derating as required | ||||
Coling Method | Fancooling | ||||
Ambient Humidity | ≤95%RH | ||||
Dimensions(H*W*D)[mm] | 151.7*101*126.8 | 249.5*155.5*159.5 | |||
Gross Weight[kg] | 1.4 | 1.5 | 3.4 | 3.5 | 3.6 |
Standard warranty[month] | 18 | ||||
Cerificates | IEC/EN 61800-5-1,IEC/EN 61800-2:2004,IEC/EN 61800-3:2004,CE |
Please follow us