Project Description

FW-BKN Mini Circuit Breaker

Introduction

Low voltage circuit breakers are widely used in low-voltage distribution system at all levels, all kinds of mechanical equipment, power control and power control and protection.under normal circumstances and disconnect the high voltage circuit in the no-load and load current.in the system failure occurs when the protection device and automatic device to match, quickly cut off the fault current, to prevent accidents, so as to ensure the safe operation of the system.

A circuit breaker is an automatically operated electrical switch designed to protect an electrical circuit from damage caused by overcurrent or overload or short circuit.

You may not know about the miniature circuit breaker.

In today’s life, we can’t live without electricity, but there are some potential safety hazards in our life. For example, when the line is short circuit, over current, over load, we will burn the electrical appliances. When a short circuit occurs in the circuit, the circuit breaker instantaneous action, disconnect the power, protect the line. If people get electric shock, the circuit breaker instantaneous action, disconnect the power, can play a security role.

Low voltage circuit breakers are widely used in low-voltage distribution system at all levels, all kinds of mechanical equipment, power control and power control and protection.

Main function of low voltage circuit breaker:

1:under normal circumstances and disconnect the high voltage circuit in the no-load and load current.

2 :in the system failure occurs when the protection device and automatic device to match, quickly cut off the fault current, to prevent accidents, so as to ensure the safe operation of the system.

 Model number FW-BKN
Brand name FULL
Place of Origin Zhejiang, China (Mainland)
Protection span Overload and short circuit  protection
Rated   current(In) 1,2,3,6,10,16,20,25,32,40,50,63A
 Characteristic B,,C,D characteristic
Pole 1P,1P+N2P,3P,3P+N4P)
 Breaking capacity AC230V:6KA AC230/400V:6KA 4.5KA AC230/400V
 Compliance standard IEC60898
 Certificate CE,CB,INMETRO.ISO9001
 Guarantee time 12 month
Tripper type Thermomagnetic type
 Material Plastic/Bakelite
 Electric life 10000 time
 Mounting Track of 35mm of
Width One 17.8mm
Terminal Square hole press line type(connect with cables of 25m㎡)
standard Rated current(A) Poles(P) Rated voltage(v) Breaking capacity(A)
BS3871-1

IEC60898

IEC157-1

BS3871-1

IEC60898

IEC157-1

1 to 40

50 to 63

1 240 6000
1,2,3,4 415 6000
50 to 63

1

1 240 4000
2,3,4 415 4000
1 220/240 10000
2,3,4 220/240 20000
2,3,4 380/415 10000
3 1 220/240 8000
2,3,4 220/240 20000
2,3,4 380/415 8000
10 to 40 1 220/240 7000
2,3,4 220/240 16000
2,3,4 380/415 8000
50 1 220/240 6000
2,3,4 220/240 10000
2,3,4 380/410 6000
63

10 to 40

10 to 40

1, 220/240 5000
2,3,4 220/240 10000
2,3,4 380/410 5000
1 240 4000
2,3,4 415 4000
1 220/240 6000
2,3,4 220/240 12000
2,3,4 380/415 6000

 Front Page  Title Document Type  Download
 circuit-breaker Circuit Breaker Catalogue
5.12MB