Project Description

GMC ac contactor

Introduction

AC contactor is widely used in power transmission system. Applicable to long-distance frequent switching on and switching end DC main circuit and large capacity control circuit in, it main control object is all motor, and can also be used for electric welder control, capacitor banks, and the electric heating device, lighting equipment and other loads. For example, power industry, industrial and mining enterprises, iron and steel plants, and some large power will use it. Can also cooperate with the fuse, the dynamic air circuit breaker, thermal relay and other electrical use, in order to better protect the line current.

An air conditioning unit is a complex system of electronic components that must work together so that your AC system can run at the right times.

Why do we need to use AC contactor?

We live around a lot of large equipment to start the knife gate will have a spark, arc, will have a security risk, if it is safe to contact the remote control is much more safe.

AC contactor is widely used in power transmission system. Applicable to long-distance frequent switching on and switching end DC main circuit and large capacity control circuit in, it main control object is all motor, and can also be used for electric welder control, capacitor banks, and the electric heating device, lighting equipment and other loads. For example, power industry, industrial and mining enterprises, iron and steel plants, and some large power will use it. Can also cooperate with the fuse, the dynamic air circuit breaker, thermal relay and other electrical use, in order to better protect the line current.

Its advantages: it has a large number of control, the action is rapid, safe and easy operation, etc., and has the function of under voltage release, the application is very extensive in industrial and agricultural production. Simple wiring. The contact point of the AC contactor is made of silver tungsten alloy, which has good electrical conductivity and high temperature resistance. Can prolong the service life of the switch, protect the electric equipment.

Type GMC-9 GMC-12 GMC-18 GMC-22 GMC-32
IEC-
60947
      Ac1 duty 20A 20A 25A 32A 50A
Ac3
duty
200-240V
380-440V
500-550V
690V
2.5KW11A 3.5KW13A 4.5KW18A 5.5KW22A 7.5KW32A
4KW9A 5.5KW12A 7.5KW18A 11KW22A 15KW32A
4KW7A 7.5KW12A 7.5KW18A 15KW22A 18.5KW28A
4KW5A 7.5KW9A 7.5KW9A 15KW18A 18.5KW21A
UL continuous current(Ith) 20A 25A 30A 32A 45A
AC
motor
Single phase
three phase
115V
230V
0.5HP 0.5HP 1HP 2HP 2HP
1 2HP 3HP 3HP 5HP
200V
230V
460V
575V
2 3HP 5HP 7HP 7.5HP
3 3HP 5HP 7.5HP 10HP
2 7.5HP 10HP 10HP 20HP
5 10HP 15HP 15HP 20HP
lifetime(Unit:10::000
time)Aux.contact
electrical
Mechanical
250 250 250 250 200
2500 2500 2500 2500 1500
Standard 1NO 1NC 1NO 1NC 1NO 1NC 1NO 1NC 2NO 2NC
Type GMC-40 GMC-50 GMC-65 GMC-75 GMC-85
IEC-
60947
      Ac1 duty 60A 80A 100A 110A 135A
Ac3
duty
200-240V
380-440V
500-550V
690V
11KW40A 15KW55A 18.5KW65A 22KW75A 25KW85A
18.5KW40A 22kw50A 30KW65A 37KW75A 45KW85A
22KW32A 30KW43A 37KW60A 45KW64A 45KW75A
22KW25A 30KW33A 37KW47A 45KW47A 45KW52A
UL continuous current(Ith) 50A 70A 80A 90A 100A
AC
motor
Single phase
three phase
115V
230V
3HP 3HP 5HP 5HP 7.5HP
5HP 7.5HP 10HP 15HP 15HP
200V
230V
460V
575V
10HP 10HP 15HP 20HP 25HP
10HP 15HP 20HP 25HP 30HP
25HP 30HP 40HP 50HP 50HP
25HP 30HP 40HP 50HP 50HP
lifetime(Unit:10::000
time)Aux.contact
electrical
Mechanical
200 200 200 200 200
1500 1000 1000 1000 1000
Standard 2NO 2NC 2NO 2NC 2NO 2NC 2NO 2NC 2NO 2NC