Project Description

LC1-K ac contactor

Introduction

AC contactor is widely used in power transmission system. Applicable to long-distance frequent switching on and switching end DC main circuit and large capacity control circuit in, it main control object is all motor, and can also be used for electric welder control, capacitor banks, and the electric heating device, lighting equipment and other loads. For example, power industry, industrial and mining enterprises, iron and steel plants, and some large power will use it. Can also cooperate with the fuse, the dynamic air circuit breaker, thermal relay and other electrical use, in order to better protect the line current.

An air conditioning unit is a complex system of electronic components that must work together so that your AC system can run at the right times.

Why do we need to use AC contactor?

We live around a lot of large equipment to start the knife gate will have a spark, arc, will have a security risk, if it is safe to contact the remote control is much more safe.

AC contactor is widely used in power transmission system. Applicable to long-distance frequent switching on and switching end DC main circuit and large capacity control circuit in, it main control object is all motor, and can also be used for electric welder control, capacitor banks, and the electric heating device, lighting equipment and other loads. For example, power industry, industrial and mining enterprises, iron and steel plants, and some large power will use it. Can also cooperate with the fuse, the dynamic air circuit breaker, thermal relay and other electrical use, in order to better protect the line current.

Its advantages: it has a large number of control, the action is rapid, safe and easy operation, etc., and has the function of under voltage release, the application is very extensive in industrial and agricultural production. Simple wiring. The contact point of the AC contactor is made of silver tungsten alloy, which has good electrical conductivity and high temperature resistance. Can prolong the service life of the switch, protect the electric equipment.

specifications\Type LC1-K06 LC1-K09 LC1-K12
Use group under AC-3 3 9 12
Rated working current(le)A 5 7.5 10
Conventional thermal current(Ith)A 16 20 20
Rated working voltage(Ue)V 380 660
Rated insullation(Ui)V 690
AC-3(6le le ) Electrical life(times) 0.5X10^6
Operation frequency 1/h 1200
AC-4(6le le ) Electrical life(times) 10X10^4
Operation frequency 1/h 300
Macnical life 3X10^6
Auxilary contact Conventional thermal current 0.5X10^6
Electrical life(times) AC-15(360VA)
DC-13(33KW)
Coil specifications Rated control voltage(Us) AC:12,24,45,110,220,380
DC:12,24,45,110,220
pick-up voltage AC:0.85~1.1Us DC:0.85~1.1Us
Releasing voltage AC:0.1~0.75Us DC:0.2~0.75Us
Coil power VA pick-up 40
Retain 4
Consumption 1.2w
Pick-up time 6~18ms
Releasing time 5~23ms
Power factor Making 0.8 Breaking 0.3