LP1-D DC contactor

Introduction

AC contactor is widely used in power transmission system. Applicable to long-distance frequent switching on and switching end DC main circuit and large capacity control circuit in, it main control object is all motor, and can also be used for electric welder control, capacitor banks, and the electric heating device, lighting equipment and other loads. For example, power industry, industrial and mining enterprises, iron and steel plants, and some large power will use it. Can also cooperate with the fuse, the dynamic air circuit breaker, thermal relay and other electrical use, in order to better protect the line current.

An air conditioning unit is a complex system of electronic components that must work together so that your AC system can run at the right times.

Why do we need to use AC contactor?

We live around a lot of large equipment to start the knife gate will have a spark, arc, will have a security risk, if it is safe to contact the remote control is much more safe.

AC contactor is widely used in power transmission system. Applicable to long-distance frequent switching on and switching end DC main circuit and large capacity control circuit in, it main control object is all motor, and can also be used for electric welder control, capacitor banks, and the electric heating device, lighting equipment and other loads. For example, power industry, industrial and mining enterprises, iron and steel plants, and some large power will use it. Can also cooperate with the fuse, the dynamic air circuit breaker, thermal relay and other electrical use, in order to better protect the line current.

Its advantages: it has a large number of control, the action is rapid, safe and easy operation, etc., and has the function of under voltage release, the application is very extensive in industrial and agricultural production. Simple wiring. The contact point of the AC contactor is made of silver tungsten alloy, which has good electrical conductivity and high temperature resistance. Can prolong the service life of the switch, protect the electric equipment.

Type Rated working
current A(AC-3)
Conventional thermal
current Ith(A)
Rated working
voltage Ue(V)
Rated insulated
voltage Uiv
Controlled power(kw) Electric life
(AC-3)(10 4)
Contacts
number
220V 380V 660V
LP1-D09 9 20 380V
660V
660V 2.2 4 5.5 100 3P+NO
3P+NC
LP1-D12 12 20 3 5.5 7.5 100
LP1-D18 18 32 4 7.5 9 100
LP1-D25 25 40 5.5 11 15 100
LP1-D32 32 50 7.5 15 18.5 80
LP1-D40 40 60 11 22 30 80 3P+NO+NC
LP1-D50 50 80 15 25 33 60
LP1-D65 65 80 18.5 37 37 60
LP1-D80 80 125 22 45 45 60
LP1-D95 95 125 25 45 45 60